Product
> Product > Joints

In case of installing drain boards on soft ground, joint devices are used to link the drainage space of each drain board without disconnection, prevent the drain boards from being disconnected due to certain tension by using a stapler, reduce materials costs by cutting overall length losses, and prevent environmental damage.
[Test Office: Korea Apparel Testing and Research Institute and FITI Testing and Research Institute]
| Division | Existing Stapler Connection | Joint Device Connection | ||
|---|---|---|---|---|
| Physical features |
Shape | ![]() |
![]() |
|
| Width | 100 ± 5 mm | 100 ± 5 mm | ||
| Thickness | More than 5mm | More than 5mm | ||
| Tensile Strength (kN/overall width) |
KS K 10319 | 2.36 | 2.36 | |
| Drainage Performance | Straight Line | 31(500kPa, 1 week) | 118(300kPa, 1 week) | |
| Curve | 29(500kPa, 1 week) | - | ||
| Division | Existing Stapler Connection | Joint Device Connection |
|---|---|---|
| Remainder Waste | 10m | None |
| Unit Price | 300 WON/m | 1,000 WON/EA |
| Costs | 3,000 WON (10m x 300 WON) | 1,000 WON |
| Costs Ratio | 3.0times more | 1.0times more |
| Feature | Extra costs for remainder Waste | Reduces materials costs, improves drainage performance, no waste |
a. Prepare joint device materials.
b. Insert lain board, starting with the protrusions of the joint device.
c. Fully insert drain board to stopper and fasten with nails.
d. Same with the other side – insert drain board in the protrusions first.
e. Fully insert drain board to stopper and fasten with nails.